Check the error
Confirm that the IX6860 shows a waste ink or absorber warning, not an unrelated mechanical or cartridge error.
Canon IX6860 · waste ink absorber reset
Looking for a Canon IX6860 resetter? Start with the printer status, not the activation key. The IX6860 must have no unrelated faults and must be recognized in the correct service mode before WIC Reset Connect can perform the waste ink reset.
The download is free. One unused key completes one reset and has no expiry date before use. Orders are normally delivered automatically by email in about one minute.

Quick diagnosis
Confirm that the IX6860 shows a waste ink or absorber warning, not an unrelated mechanical or cartridge error.
Keep this page on hold until the exact model-specific sequence is confirmed.
Run WIC Reset Connect, keep USB stable, then switch the printer off for at least 10 seconds before normal startup.
Before using a key: the printer must have no pending jobs or unrelated errors. Use one direct USB connection and leave only the target Canon IX6860 connected.
Understand the warning
The Canon iX-series business inkjet printer estimates how much waste ink has been collected during cleaning and maintenance. When the programmed limit is reached, the printer may display 1700 as an advance warning or stop with 5B00 and a waste ink absorber message. The reset clears that electronic counter; it does not fix an unrelated print-head, cartridge or power fault.
For this Canon model, WIC Reset Connect performs the counter operation after service mode is accepted. Do not enter the Connect key into WIC Reset Utility. Disconnect other Epson and Canon equipment, keep only the IX6860 attached and wait for a clear success message before restarting.
Use the official WIC Reset Connect download and a key intended for this workflow, with technical support available if the program returns an error.
Keep the program message and order details if a valid attempt fails. A failed attempt can be reviewed instead of repeating random steps.
An unused activation key does not expire. One key is consumed by one completed reset on one supported printer.
Resettable Canon absorber codes: on supported models, WIC Reset Connect can clear the waste ink counter behind Canon support codes 5B00, 5B01, 5B02, 5B03 and 5B04. The exact code displayed depends on the printer and region.
Physical maintenance still matters: software resets the electronic counter only. If ink is leaking or the absorber/pads are saturated, clean or replace the maintenance components before continued printing.
Step-by-step procedure
Canon service-mode sequences vary by printer series, control panel and regional model. Do not guess the number of button presses or copy a sequence from a similar printer. Use the Canon service-mode guide below and choose the method that matches your exact model or series.
Turn the printer off, leave power connected, clear pending print jobs and connect it directly to a Windows computer with a USB data cable. Disconnect other Canon and Epson devices.
Check the model and series in the complete WIC Reset guide. It explains the POWER, STOP/RESET, HOME or touchscreen combinations used by different Canon families.
Use only the method shown for your printer family. Count every press carefully, release the buttons in the stated order and wait until the printer finishes entering maintenance mode.
The printer should settle without an unrelated flashing error and Windows should detect the service-mode device. Only then open WIC Reset Connect and start the counter reset.
You can also use the complete Canon reset manual. If the printer does not enter service mode, switch it off, unplug it for 10–15 seconds and repeat the correct model-family method.
Requirements and common mistakes
You can also open the video instruction library or verify another model in the supported printer finder.
Troubleshooting
Change to a direct motherboard USB port, remove hubs, try another data-capable cable and disconnect other Canon or Epson devices. Restart Windows if the maintenance device was not installed correctly.
Write down the exact code and check cartridges, paper path and power status. WIC Reset Connect cannot bypass an unrelated fault that prevents the printer from reaching the required maintenance state.
Do not repeatedly reuse random software or button combinations. Save the log, screenshot and key details. If a valid attempt was interrupted, use the replacement-key request or contact support.
Confirm that the program reported success and that the printer was switched off for about 10 seconds. Check the exact counter or error again rather than assuming every service message is the waste ink counter.
Frequently asked questions
Prepare a direct USB connection, enter the correct model-specific service mode and run WIC Reset Connect with one valid key. Restart the printer after the success message.
The procedure is intended for waste ink absorber counter conditions associated with support codes 5B00, 5B01, 5B02, 5B03 and 5B04, plus related absorber warnings such as 1700. It does not repair a cartridge, scanner, paper-feed or print-head fault.
No. Service-mode communication requires a direct USB data connection to a Windows 7–11 computer.
The button sequence enters service mode. WIC Reset Connect performs the electronic counter reset after Windows detects the printer.
The current reference does not identify an exact sequence for this model. The page must not be imported until the procedure is confirmed.
No. An unused WIC Reset Connect key has no expiry date before use. One key completes one reset.
No. The program clears the electronic counter. A saturated or leaking absorber must be cleaned or replaced before continued printing.
Keep the order email, key, screenshot and complete program message or log. Do not repeatedly change the procedure without recording the result.
Ready to continue?
Confirm the model, connection and printer status first. Then use WIC Reset Connect with one activation key and keep the result message until the printer has restarted normally.